Effect of electrostatic charge in plastic spacers on the lung delivery of HFA-salbutamol in children.

    Home Publications Effect of electrostatic charge in plastic spacers on the lung delivery of HFA-salbutamol in children.
    NextPrevious

    Effect of electrostatic charge in plastic spacers on the lung delivery of HFA-salbutamol in children.

    By Dansk Børne Astma Center | Publications | Comments are Closed | 11 March, 1999 |

    Br J Clin Pharmacol. 1999 Mar
    Anhøj J, Bisgaard H, Lipworth BJ.

    Abstract
    AIMS:
    The effect of the electrostatic charge in plastic spacers in vivo on drug delivery to the lung of hydrofluoroalkane (HFA) salbutamol spray was studied in children.

    METHODS:
    Five children, aged 7-12 years, were included in a 3-way crossover randomised single-blind trial. Salbutamol HFA spray was delivered on 3 different study days from plastic spacers with mouthpiece. Pre-treatment of the spacers differed between study days: (a) Non-electrostatic 350 ml Babyhaler (coated with benzalkonium chloride) (b) New 350 ml Babyhaler (rinsed in water), and (c) New 145 ml AeroChamber (rinsed in water). Plasma salbutamol was measured before and 5, 10, 15 and 20 min after inhalation of four single puffs of 100 microg salbutamol. Cmax and Cav (5-20min) were calculated as a reflection of lung dose.

    RESULTS:
    For Cmax: (A) Non-electrostatic Babyhaler 4.3 ng ml(-1) (B) New Babyhaler 1.9 ng ml(-1) (C) New AeroChamber 1.6 ng ml(-1): AvsB (95% CI for difference 0.5-4.5 ng ml(-1)), A vs C (95% CI for difference 0.7-4.8 ng ml(-1)). The geometric mean ratio for A:B was 2.4 fold, and for A:C was 2.9 fold. The values for Cav were similar with ratios for A:B of 2.4 fold, and A: C of 4.1 fold. The nonelectrostatic Babyhaler delivered a significantly (P<0.05) higher lung dose (for both Cmax and Cav) than either of the other two spacers.

    CONCLUSIONS:
    The electrostatic charge in plastic spacers reduces lung dose in children by more than two-fold. This is clinically significant and the use of potentially electrostatically charged spacers should be avoided.

    PMID: 10215759

    No tags.
    NextPrevious

    CONTACT

    COPSAC
    Copenhagen Prospective Studies on Asthma in Childhood
    Copenhagen University Hospital, Herlev-Gentofte
    phone +45 3867 7360
    contact@copsac.com
    COPSAC • Copenhagen University Hospital, Herlev-Gentofte • Denmark © 2023
    • About COPSAC
      • About
      • Organization Diagram
      • Board of Directors
      • Research team
      • Location
      • Funding
      • Logo
      • Open positions
    • COPSAC cohorts
      • COPSAC2000 cohort
      • COPSAC2010 cohort
      • COPSACSEVERE cohort
      • COPSACACUTE cohort
      • Methods
      • Data overview
        • COPSAC2000 Clinic
        • COPSAC2000 Exposures
        • COPSAC2000 Omics
        • COPSAC2000 Biobank
        • COPSAC2010 Clinic
        • COPSAC2010 Exposures
        • COPSAC2010 Omics
        • COPSAC2010 Biobank
    • Dissemination
      • Theses
      • Literature for parents
    • Research Projects
      • RestoreGut
      • COPSYCH Research Alliance
      • HEDIMED Consortium
      • EDIAQI Consortium
      • EAGLE Consortium
      • EarlyVir
    • Strategy
    • ‌
    COPSAC