COPSAC COPSAC COPSAC COPSAC
  • About COPSAC
    • About
    • Organization Diagram
    • Board of Directors
    • Research team
    • Location
    • Funding
    • Logo
    • Open positions
  • COPSAC cohorts
    • COPSAC2000 cohort
    • COPSAC2010 cohort
    • COPSACSEVERE cohort
    • COPSACACUTE cohort
    • Methods
    • Data overview
      • COPSAC2000 Clinic
      • COPSAC2000 Exposures
      • COPSAC2000 Omics
      • COPSAC2000 Biobank
      • COPSAC2010 Clinic
      • COPSAC2010 Exposures
      • COPSAC2010 Omics
      • COPSAC2010 Biobank
  • Dissemination
    • Theses
    • Literature for parents
  • Research Projects
    • RestoreGut
    • COPSYCH Research Alliance
    • HEDIMED Consortium
    • EDIAQI Consortium
    • EAGLE Consortium
    • EarlyVir
  • Strategy
  • ‌

Allergen-induced increase of eosinophil cationic protein in nasal lavage fluid: effect of the glucocorticoid budesonide.

    Home Publications Allergen-induced increase of eosinophil cationic protein in nasal lavage fluid: effect of the glucocorticoid budesonide.
    NextPrevious

    Allergen-induced increase of eosinophil cationic protein in nasal lavage fluid: effect of the glucocorticoid budesonide.

    By Dansk Børne Astma Center | Publications | Comments are Closed | 13 May, 1991 |

    J Allergy Clin Immunol. 1990 May
    Bisgaard H, Grønborg H, Mygind N, Dahl R, Lindqvist N, Venge P.

    Abstract
    It was our aim to study the effect of nasal allergen provocation on the concentration of eosinophil cationic protein (ECP) in nasal lavage fluid, with and without glucocorticoid pretreatment. Twenty grass-pollen sensitive volunteers were provoked outside the pollen season on 2 consecutive days after pretreatment for 2 weeks with the glucocorticoid, budesonide, as a nasal spray (400 micrograms/day) and with placebo with a double-blind, crossover design. Nasal lavage fluid was repeatedly collected during a 10-hour period to study both early and late-phase responses. 99mTechnetium-albumin was added to the lavage fluid, making it possible to calculate the amount of secretion and the degree of dilution. The results were as follows: (1) There was no correlation between ECP concentration and dilution factor in the individual samples. (2) The mean concentration of ECP in lavage fluid from untreated, prechallenge noses was 400 micrograms/L. (3) The ECP level did not increase during the early phase response. (4) There was a late occurring increase in the ECP concentration (6 to 24 hours). (5) This increase was completely inhibited by budesonide pretreatment. (6) The glucocorticoid therapy also reduced the prechallenge ECP concentration. In conclusion, allergen provocation in the nose results in a late occurring increase of ECP in nasal lavage fluid, and one of the therapeutic effects of topical glucocorticoid therapy may be an inhibition of the allergen-induced increase of this cytotoxic molecule.

    PMID: 2185293

    No tags.
    NextPrevious

    CONTACT

    COPSAC
    Copenhagen Prospective Studies on Asthma in Childhood
    Copenhagen University Hospital, Herlev-Gentofte
    phone +45 3867 7360
    contact@copsac.com
    COPSAC • Copenhagen University Hospital, Herlev-Gentofte • Denmark © 2023
    • About COPSAC
      • About
      • Organization Diagram
      • Board of Directors
      • Research team
      • Location
      • Funding
      • Logo
      • Open positions
    • COPSAC cohorts
      • COPSAC2000 cohort
      • COPSAC2010 cohort
      • COPSACSEVERE cohort
      • COPSACACUTE cohort
      • Methods
      • Data overview
        • COPSAC2000 Clinic
        • COPSAC2000 Exposures
        • COPSAC2000 Omics
        • COPSAC2000 Biobank
        • COPSAC2010 Clinic
        • COPSAC2010 Exposures
        • COPSAC2010 Omics
        • COPSAC2010 Biobank
    • Dissemination
      • Theses
      • Literature for parents
    • Research Projects
      • RestoreGut
      • COPSYCH Research Alliance
      • HEDIMED Consortium
      • EDIAQI Consortium
      • EAGLE Consortium
      • EarlyVir
    • Strategy
    • ‌
    COPSAC