Accuracy of whole-body plethysmography requires biological calibration.

    Home Publications Accuracy of whole-body plethysmography requires biological calibration.
    NextPrevious

    Accuracy of whole-body plethysmography requires biological calibration.

    By Dansk Børne Astma Center | Publications | Comments are Closed | 11 June, 2009 |

    Chest. 2009 Jun
    Poorisrisak P, Vrang C, Henriksen JM, Klug B, Hanel B, Bisgaard H.

    Abstract
    BACKGROUND:
    Specific airway resistance (sRaw) measured by whole-body plethysmography in young children is increasingly used in research and clinical practice. The method is precise and feasible. However, there is no available method for calibration of the resistance measure, which raises concern of accuracy. Our aim was to determine the agreement of sRaw measurements in six centers and expand normative sRaw values for nonasthmatic children including these centers.

    METHOD:
    Identical hardware with different software versions was used at the six centers. Measurements followed a standard operating procedure: (1) seven healthy young children were brought to each of the six centers for sRaw measurements; and (2) 105 healthy preschool children (52 boys; mean age, 5.1 years; interquartile range, 4.3 to 6.0) were recruited locally for sRaw measurements.

    RESULTS:
    (1) The sRaw of the seven-children study group was significantly lower at two centers compared with the other four centers, and one center had significantly higher sRaw than all the other centers (p < 0.05). Error in the factory settings of the software was subsequently discovered in one of the deviating centers. (2) Normative data (105 preschool children) were generated and were without significant difference between centers and independent of height, weight, age, and gender. We subsequently pooled these normative data (105 children) with our previous data from 121 healthy young children (overall mean sRaw, 1.27; SD, 0.25).

    CONCLUSION:
    Control using biological standards revealed errors in the factory setting and highlights the need for developing methods for verification of resistance measures to assure accuracy. Normative data were subsequently generated. Importantly, other centers using such normative data should first consider proper calibration before applying reference values.

    Comment in
    Whole-body plethysmography. The human factor. [Chest. 2009]

    PMID: 19497894

    No tags.
    NextPrevious

    CONTACT

    COPSAC
    Copenhagen Prospective Studies on Asthma in Childhood
    Copenhagen University Hospital, Herlev-Gentofte
    phone +45 3867 7360
    contact@copsac.com
    COPSAC • Copenhagen University Hospital, Herlev-Gentofte • Denmark © 2023
    • About COPSAC
      • About
      • Organization Diagram
      • Board of Directors
      • Research team
      • Location
      • Funding
      • Logo
      • Open positions
    • COPSAC cohorts
      • COPSAC2000 cohort
      • COPSAC2010 cohort
      • COPSACSEVERE cohort
      • COPSACACUTE cohort
      • Methods
      • Data overview
        • COPSAC2000 Clinic
        • COPSAC2000 Exposures
        • COPSAC2000 Omics
        • COPSAC2000 Biobank
        • COPSAC2010 Clinic
        • COPSAC2010 Exposures
        • COPSAC2010 Omics
        • COPSAC2010 Biobank
    • Dissemination
      • Theses
      • Literature for parents
    • Research Projects
      • RestoreGut
      • COPSYCH Research Alliance
      • HEDIMED Consortium
      • EDIAQI Consortium
      • EAGLE Consortium
      • EarlyVir
    • Strategy
    • ‌
    COPSAC