COPSAC COPSAC COPSAC COPSAC
  • About COPSAC
    • About
    • Organization Diagram
    • Board of Directors
    • Research team
    • Location
    • Funding
    • Logo
    • Open positions
  • COPSAC cohorts
    • COPSAC2000 cohort
    • COPSAC2010 cohort
    • COPSACSEVERE cohort
    • COPSACACUTE cohort
    • Methods
    • Data overview
      • COPSAC2000 Clinic
      • COPSAC2000 Exposures
      • COPSAC2000 Omics
      • COPSAC2000 Biobank
      • COPSAC2010 Clinic
      • COPSAC2010 Exposures
      • COPSAC2010 Omics
      • COPSAC2010 Biobank
  • Dissemination
    • Theses
    • Literature for parents
  • Research Projects
    • RestoreGut
    • COPSYCH Research Alliance
    • HEDIMED Consortium
    • EDIAQI Consortium
    • EAGLE Consortium
    • EarlyVir
  • Strategy
  • ‌

A metal aerosol holding chamber devised for young children with asthma.

    Home Publications A metal aerosol holding chamber devised for young children with asthma.
    NextPrevious

    A metal aerosol holding chamber devised for young children with asthma.

    By Dansk Børne Astma Center | Publications | Comments are Closed | 13 May, 1995 |

    Eur Respir J. 1995 May
    Bisgaard H.

    Abstract
    The low tidal volume and flow in preschool children may reduce the efficiency of aerosol delivery from a pressurized metered-dose inhaler (pMDI) through a traditional holding chamber. A prototype small-volume steel holding chamber with two one-way valves was devised to prolong aerosol availability in the chamber and to ensure unidirectional airflow. Dead space between the valves was minimized to less than 2 ml. The dose-delivery and rate of passive disappearance of a budesonide pMDI aerosol were compared between this prototype and the large-volume, single-valved plastic Nebuhaler, in 164 asthmatic children less than 8 yrs of age. In vitro, the half life of aerosol disappearance in the steel prototype and the plastic Nebuhaler was > 30 s and 9 s, respectively. In vivo, the prototype delivered an age-independent mean dose of 38% of the nominal dose, and the Nebuhaler delivered an age-dependent mean dose, ranging from 42% of the nominal dose in children > or = 4 yrs to 19% of the nominal dose in infants. We conclude that the use of plastic for holding chambers may influence dose-delivery, and single-valve control may cause age-dependent dose-delivery. Reproducible age-independent drug-delivery may be achieved by pMDI aerosol inhaled through a small-volume metal holding chamber with separate inlet and outlet valves and minimized dead space. This holding chamber would improve the possibilities of aerosol therapy for young children.

    PMID: 7656962

    No tags.
    NextPrevious

    CONTACT

    COPSAC
    Copenhagen Prospective Studies on Asthma in Childhood
    Copenhagen University Hospital, Herlev-Gentofte
    phone +45 3867 7360
    contact@copsac.com
    COPSAC • Copenhagen University Hospital, Herlev-Gentofte • Denmark © 2023
    • About COPSAC
      • About
      • Organization Diagram
      • Board of Directors
      • Research team
      • Location
      • Funding
      • Logo
      • Open positions
    • COPSAC cohorts
      • COPSAC2000 cohort
      • COPSAC2010 cohort
      • COPSACSEVERE cohort
      • COPSACACUTE cohort
      • Methods
      • Data overview
        • COPSAC2000 Clinic
        • COPSAC2000 Exposures
        • COPSAC2000 Omics
        • COPSAC2000 Biobank
        • COPSAC2010 Clinic
        • COPSAC2010 Exposures
        • COPSAC2010 Omics
        • COPSAC2010 Biobank
    • Dissemination
      • Theses
      • Literature for parents
    • Research Projects
      • RestoreGut
      • COPSYCH Research Alliance
      • HEDIMED Consortium
      • EDIAQI Consortium
      • EAGLE Consortium
      • EarlyVir
    • Strategy
    • ‌
    COPSAC