COPSAC COPSAC COPSAC COPSAC
  • About COPSAC
    • About
    • Organization Diagram
    • Board of Directors
    • Research team
    • Location
    • Funding
    • Logo
    • Open positions
  • COPSAC cohorts
    • COPSAC2000 cohort
    • COPSAC2010 cohort
    • COPSACSEVERE cohort
    • COPSACACUTE cohort
    • COPSACDailyGutcohort
    • Methods
    • Data overview
      • COPSAC2000 Clinic
      • COPSAC2000 Exposures
      • COPSAC2000 Omics
      • COPSAC2000 Biobank
      • COPSAC2010 Clinic
      • COPSAC2010 Exposures
      • COPSAC2010 Omics
      • COPSAC2010 Biobank
  • Dissemination
    • Theses
    • Literature for parents
  • Research Projects
    • RestoreGut
    • COPSYCH Research Alliance
    • HEDIMED Consortium
    • EDIAQI Consortium
    • EAGLE Consortium
    • EarlyVir
  • Strategy
  • ‌

Quantitation of microcirculatory blood flow changes in human cutaneous tissue induced by inflammatory mediators.

    Home Publications Quantitation of microcirculatory blood flow changes in human cutaneous tissue induced by inflammatory mediators.
    NextPrevious

    Quantitation of microcirculatory blood flow changes in human cutaneous tissue induced by inflammatory mediators.

    By Dansk Børne Astma Center | Publications | Comments are Closed | 18 September, 1984 |

    J Invest Dermatol. 1984 Sep
    Bisgaard H, Kristensen JK.

    Abstract
    The cutaneous microcirculation is a desirable model for pharmacologic and physiologic studies of inflammatory mediators. For exact measurements of the induced blood flow changes, two objective methods are introduced. The laser-Doppler flowmeter and the 133Xe washout technique have formerly been used for measurement of the undisturbed cutaneous blood flow. We have modified these methods to measure changes in the blood flow following intracutaneous deposition of a vasodilator, leukotriene D4. When compared with a metric estimate of the erythemal response, the two new methods were found to be more sensitive than the traditional estimate of cutaneous blood flow changes. Both methods exhibited a good sensitivity and reproducibility when applied simultaneously, although the 133Xe washout technique appeared to be able to separate interindividual differences that could not be recognized by the laser-Doppler technique. Even though the laser-Doppler technique is superior in simplicity of use, the 133Xe washout technique is recommended for exact measurements.

    PMID: 6470522

    No tags.
    NextPrevious

    CONTACT

    COPSAC
    Copenhagen Prospective Studies on Asthma in Childhood
    Copenhagen University Hospital, Herlev-Gentofte
    phone +45 3867 7360
    contact@copsac.com
    COPSAC • Copenhagen University Hospital, Herlev-Gentofte • Denmark © 2023
    • About COPSAC
      • About
      • Organization Diagram
      • Board of Directors
      • Research team
      • Location
      • Funding
      • Logo
      • Open positions
    • COPSAC cohorts
      • COPSAC2000 cohort
      • COPSAC2010 cohort
      • COPSACSEVERE cohort
      • COPSACACUTE cohort
      • COPSACDailyGutcohort
      • Methods
      • Data overview
        • COPSAC2000 Clinic
        • COPSAC2000 Exposures
        • COPSAC2000 Omics
        • COPSAC2000 Biobank
        • COPSAC2010 Clinic
        • COPSAC2010 Exposures
        • COPSAC2010 Omics
        • COPSAC2010 Biobank
    • Dissemination
      • Theses
      • Literature for parents
    • Research Projects
      • RestoreGut
      • COPSYCH Research Alliance
      • HEDIMED Consortium
      • EDIAQI Consortium
      • EAGLE Consortium
      • EarlyVir
    • Strategy
    • ‌
    COPSAC