  Title Feasibility of repetitive lung function measurements by raised volume rapid thoracoabdominal compression during methacholine challenge in young infants Type Journal Article
  Year (down) 2008 Publication Chest Abbreviated Journal Chest  
  Volume 133 Issue 1 Pages 115-122  
  Keywords Feasibility Studies; Humans; Infant; *Methacholine Chloride; Respiratory Function Tests/*methods  
  Abstract BACKGROUND: The aim of the study was to evaluate the feasibility of lung function measurements by the raised volume rapid thoracoabdominal compression (RVRTC) technique during bronchial methacholine challenge in young infants. METHOD: Four hundred two healthy infants were tested at 1 month of age with RVRTC during repeated methacholine challenges with quadrupling doses from 0.037 to 16.674 mumol. RESULTS: Measurement of baseline lung function was successful in 99% and the provocative dose (PD) was achieved in 79% of infants by forced expiratory volume in 0.5 s (FEV(0.5)). Additionally, the PD was successfully measured in 87% by transcutaneous oxygen pressure. No serious adverse events were observed during testing or after discharge from the clinic. The methacholine dose range was appropriate as PD could be determined in the majority of infants. FEV(0.5) values in 21% of infants dropped > 40% during the test. Short-lasting, self-limiting episodes of hypoxemia of < 80% occurred in 1% of infants and bradycardia < 90 beats/min in 19% of infants. The most common observations by parents were changes in the patterns of sleeping (95%), eating (57%), and behavior (58%) of the infant after hospital discharge. The mean acceptability rating among parents was 8 on a scale from 1 to 10, with 13% rating < or = 5. It took one operator 3 h to complete the test, with the actual lung function testing accounting for half the time. CONCLUSION: This very comprehensive experience with standardized measurements of lung function by RVRTC during methacholine challenge in young infants in a single center leads us to conclude that the test is feasible and safe to perform in asymptomatic young infants.  
  Address Danish Pediatric Asthma Center, Department of Pediatrics, Copenhagen University Hospital, Gentofte, Niels Andersens Vej 65, DK-2900 Hellerup, Denmark  
  Corporate Author Thesis  
  Impact Factor 07,483 First Author Loland, L. Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Senior Author Bisgaard, H.  
  ISSN 0012-3692 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:17951623 Approved no  